Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 110
Filtrar
1.
RSBO (Impr.) ; 10(4): 193-401, Oct.-Dec. 2013. ilus
Artigo em Inglês | LILACS | ID: lil-766093

RESUMO

Introduction: Favourable manipulation of images may be the greatest advantage of the digital radiographic compared to the conventional film. The current development of the cost-benefit of intra- and extraoral digital technology, besides the increase of computerized practices has turned the digital image into a superior alternative to conventional radiographs, in several aspects. Objective: To demonstrate image adjustments on digital panoramic radiographs using Adobe Photoshop CS3 ( Creative Suite 3) software in order to enhance digital images. Case reports: Digital treatment was conducted in two different cases using two filters available in Adobe Photoshop CS3: Smart Sharpen and Unsharp-Mask. Both filters improve overall image quality. In the second case, after brightness and contrast adjustments, it was possible to have a detailed visualization of radiopaque and radiolucent areas. Conclusion: The application of brightness and contrast adjustments and filters are feasible methods in order to achieve diagnostic precision.

2.
RGO (Porto Alegre) ; 61(3): 319-325, jul.-set. 2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-691746

RESUMO

Objective: To verify the possibility of using the digital imaging as a control of the conditions of automatic radiographic processing. Methods: Radiographic films were standardly exposed and processed, at 4 different temperatures at the beginning of the daily working of a RadiologyClinics, which were digitized and analyzed by Digora for Windows 1.5.1 software, regarding to the radiographic densities, that is, the greylevel. Results: Based on the results it was possible to conclude that there was a ranging in the grey level, because of either the processing degree of the image on the four areas evaluated of each film or at the four temperatures studied which were statistically significant. The characteristic tracings also displayed these differences and the deterioration degree of the image quality due to the consuming of the processing solution. Conclusion: The results indicate that the evaluation of the digital image by Digora for Windows 1.5.1 software is efficient and allows the quality control of the radiographic processing properly, showing that the variation of the grey levels indicate the consuming of action of the processing solutions.


Objetivo: Avaliar a possibilidade de usar a imagem digital como avaliadora das condições de processamento radiográfico automático. Métodos: Usando filmes radiográficos expostos e processados padronizadamente, em 4 temperaturas diferentes no início dos trabalhos diários de umaClínica de Radiologia Odontológica, que foram digitalizadas e observadas pelo software do Digora for Windows 1.5.1, quanto às densidadesradiográficas, ou seja, o nível de cinza. Resultados: As tabelas e gráficos apresentados mostram que existe uma variação do nível de cinza, seja do grau de processamento da imagem nas quatro áreas avaliadas de cada filme e nas quatro temperaturas estudadas que são estatisticamente significantes. Os traçados característicos também mostram estas diferenças e o grau de deterioração da qualidade da imagem pelo desgaste da solução de processamento. Conclusão: Nossos resultados indicam que a avaliação da imagem digital, pelo software do Digora for Windows 1.5.1 é eficiente e permite o controle de qualidade do processamento radiográfico de forma adequada, mostrando que a variação dos níveis de cinza indicam o desgaste da ação dassoluções de processamento.


Assuntos
Controle de Qualidade , Filme para Raios X , Software
3.
Pesqui. bras. odontopediatria clín. integr ; 12(2): 217-222, jul. 2012. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-874601

RESUMO

Objetivo: Avaliar a existência de diferenças nas imagens de radiografias panorâmicas por meio de um estudo radiomorfométrico. Método: Foi realizado um estudo observacional, sendo a amostra composta por radiografias panorâmicas de 60 pacientes de ambos os sexos, dividida em três grupos etários (n=20): G1: 20-30, G2: 30-45 e G3: 45-60. As radiografias foram digitalizadas e analisadas. O Índice panorâmico mandibular, a Altura original da mandíbula e a Porcentagem do osso reabsorvido foram calculados e comparados por meio dos resultados da média, do desvio padrão e do coeficiente de variação de cada medida. Resultados: Na comparação entre os gêneros, as alterações foram mais evidentes nas medidas de Forame mentual - crista óssea (FC) e na Porcentagem de reabsorção óssea alveolar (%AO). Foi observada uma pequena diferença numérica entre os lados direito e esquerdo nas avaliações das estruturas ósseas mandibulares (Altura total da mandíbula e na Proporção AM/AF). Conclusões: Como as variações entre as medidas não foram muito discrepantes, sugere-se que as medidas da Altura total da mandíbula (AM), da Altura do forame mentual-crista óssea (FC) e da Porcentagem de reabsorção óssea (%AO), devam ser consideradas como um seguimento que inclua os períodos de ganho ou perda de cálcio, identificados como um fator de risco de osteoporose.


Objective: Evaluation of the existence of differences in images of panoramic radiographs through a radiomorfometric study. Method: An observational study was conducted using 60 panoramic radiograph images of 60 different patients of both sex, divided in three age groups (n= 20): G1: 20-30, G2: 30-45 and G3: 45 - 60. The radiographs were digitized and analyzed. The Panoramic mandibular index, the original height of the mandible and the percentage of bone reabsorbed were calculated and compared through the mean, standard deviation and coefficient of variation results. Results: The results were most evident considering the distance between mentual foramen and alveolar ridge, and the percentage of alveolar bone loss, when the genders were compared. A small numerical difference was observed between right and left sides in the evaluations of mandibular bone structures. Conclusions: As the variations between the measures were not very discrepant, it is suggested that measures of Total Mandibular Height, Mentual Foramen Alveolar Bone Ridge in the Percentage of Bone Resorption should be considered in the follow-up periods which includes calcium gains or loss, identified as a risk factor of osteoporosis.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Osteoporose/diagnóstico , Osteoporose/patologia , Radiografia Dentária/métodos , Radiografia Dentária , Radiografia Panorâmica/métodos , Radiografia Panorâmica , Reabsorção Óssea , Interpretação Estatística de Dados , Distribuição por Idade e Sexo , Estudos Observacionais como Assunto
4.
Dental press j. orthod. (Impr.) ; 17(2): 90-96, Mar.-Apr. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-626374

RESUMO

INTRODUCTION: Among the sleep disorders reported by the American Academy of Sleep, the most common is obstructive sleep apnea-hypopnea syndrome (OSAHS), which is caused by difficulties in air passage and complete interruption of air flow in the airway. This syndrome is associated with increased morbidity and mortality in apneic individuals. OBJECTIVE: It was the objective of this paper to evaluate a removable mandibular advancement device as it provides a noninvasive, straightforward treatment readily accepted by patients. METHODS: In this study, 15 patients without temporomandibular disorders (TMD) and with excessive daytime sleepiness or snoring were evaluated. Data were collected by means of: Polysomnography before and after placement of an intraoral appliance, analysis of TMD signs and symptoms using a patient history questionnaire, muscle and TMJ palpation. RESULTS: After treatment, the statistical analysis (t-test, and the "before and after" test) showed a mean reduction of 77.6% (p=0.001) in the apnea-hypopnea index, an increase in lowest oxyhemoglobin saturation (p=0.05), decrease in desaturation (p=0.05), decrease in micro-awakenings or EEG arousals (p=0.05) and highly significant improvement in daytime sleepiness (p=0.005), measured by the Epworth Sleepiness Scale. No TMD appeared during the monitoring period. CONCLUSION: The oral device developed in this study was considered effective for mild to moderate OSAHS.

5.
Rev. Assoc. Paul. Cir. Dent ; 64(6): 437-443, nov.-dez. 2010.
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-590253

RESUMO

Objetivo: O propósito deste trabalho foi avaliar quantitativamente, através da tomografia computadorizada de feixe cônico, a presença de linhas hipodensas em diferentes situações de procedimentos operatórios endodôntico e protético. Material e Métodos: Para a pesquisa foram utilizados 32 dentes incisivos centrais superiores, submetidos a exames com o aparelho Newtom 3G, em quatro momentos distintos: dentes não manipulados; após a realização de tratamento endodôntico; após a cimentação do núcleo metálico intrarradicular e após a remoção deste núcleo com aparelho de ultrassom. Resultados: Verificou-se que a maior quantidade de linhas hipodensas ocorreu nos dentes após remoção do núcleo intrarradicular com ultrassom, decrescendo para os dentes somente com tratamento endo- dôntico, diminuindo nos dentes com núcleos cimentados, e em menor número nos dentes não manipulados.


Objective: The objective of this study was to evaluate quantitatively the presence of lines radiolucency in different situations of procedures endodontics and prosthetic using cone beam computed tomography. Matherial and methods: For the research 32 incisive superior central teeth were selected and submitted the cone beam computed tomography - Newtom 3G, according the following moments: teeth not manipulated; after endodontic treatment; after placement of the endodontic post and after the endodontic post removal using ultrasonic instrumentation.


Assuntos
Humanos , Masculino , Feminino , Retenção em Prótese Dentária/efeitos adversos , Preparo do Dente , Tomografia Computadorizada de Feixe Cônico/métodos
6.
J Biomed Mater Res A ; 95(3): 932-9, 2010 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20845492

RESUMO

Latex extracted from Hevea brasiliensis was used as an occlusive membrane for guided bone regeneration. Twenty-four rabbits were divided in two groups: treated and control group. Critical size bone defects (2 cm × 1 cm) were surgically made in the rabbit calvarium. Two latex membranes were implanted in each animal of the treated group, whereas the control defect was filled only with autogenous blood clot. After 15, 30, 60, and 120 days, animals from each group were euthanized, and the samples with regenerated bone were removed. No signs of allergy or rejection were noticed around the calvarial bone defect of the treated group. In the histological analysis, no foreign body inflammatory reaction was observed in the adjacent tissues in contact with the membranes demonstrating that latex can be used at injured sites as an aid in the healing process. Histological analysis, digital radiography, and electron spin resonance were used to evaluate the progress of bone repair. The results show significant differences between groups (p < 0.05) suggesting that latex membranes accelerates healing in critical bone defects.


Assuntos
Regeneração Óssea/fisiologia , Regeneração Tecidual Guiada , Látex , Animais , Materiais Biocompatíveis , Calcificação Fisiológica , Regeneração Tecidual Guiada/instrumentação , Regeneração Tecidual Guiada/métodos , Masculino , Teste de Materiais , Coelhos , Crânio/patologia , Crânio/cirurgia , Cicatrização
7.
Dental press j. orthod. (Impr.) ; 15(4): 124-132, jul.-ago. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-555742

RESUMO

OBJETIVO: avaliar métodos de digitalização indireta de radiografias cefalométricas em comparação ao método digital direto. MÉTODOS: a amostra foi composta de dez radiografias cefalométricas adquiridas pelo Orthopantomograph OP100/Orthocef OC100 (GE - Instrumentarium), digital direto. As imagens foram inseridas no programa Adobe Photoshop® e cinco pontos cefalométricos foram marcados. Procedeu-se a impressão em transparência e foi feita a digitalização indireta das imagens impressas, por meio das câmeras fotográficas digitais Sony® DSC-W5 e Canon® Rebel XT/EOS 350D, fixas em estativa, nas distâncias de 25cm e 60cm e com o scanner Scan Jet 4C Hewlett Packard®. As imagens diretas e indiretas foram inseridas e calibradas no software Radiocef Studio (Radiomemory®, Brasil), marcando-se o centro dos pontos previamente assinalados. A análise cefalométrica computadorizada gerou três grandezas angulares e quatro lineares, as quais foram submetidas a tratamento estatístico. RESULTADOS: as imagens do scanner Scan Jet 4C HP® demonstraram pequenas alterações significativas, porém, sem relevância clínica. Quando da digitalização a 60cm da radiografia, as duas câmeras causaram distorções que foram significativas mas clinicamente aceitáveis; e, a 25cm, causaram as maiores distorções, com importância clínica, na Canon® Rebel XT. CONCLUSÃO: o scanner Scan Jet 4C HP® com leitor de transparências foi o melhor método e as câmeras operando a 60cm mostraram-se adequadas para digitalização de radiografias. As câmeras na distância de 25cm causaram distorções na imagem que alteraram as medidas lineares, podendo a Canon® Rebel XT comprometer o diagnóstico ortodôntico.


OBJECTIVE: To evaluate the indirect digitization method of cephalometric radiographs in comparison with the direct digital method. METHODS: The sample was composed of ten cephalometric radiographs acquired by Orthopantomograph OP100/Orthocef OC100 (GE - Instrumentarium), digital direct. In the AdobeÕ Photoshop program, five cephalometric landmarks were set in the images and the impression in transparencies was made. The indirect digitization of the images was performed through the SonyÕ DSC-W5 and CanonÕ Rebel XT/EOS 350D digital photographic cameras-fixed in a copy stand, at the distances of 25 cm and 60 cm-and through the Hewlett PackardÕ Scan Jet 4C scanner. The direct digital images and the indirect ones were inserted and gauged in the Radiocef Studio (RadiomemoryÕ, Brazil) software and the center of the previously marked landmarks was set. The cephalometric computerized analysis generated three angular measurements and four linear ones which were submitted to statistical analysis. RESULTS: The images from the scanner demonstrated small statistically significant alterations, without clinical significance. When digitizing the radiographs at 60 cm, both cameras caused distortions which were statistically significant, but clinically acceptable. At 25 cm, the cameras caused the largest distortions, being more expressive and with clinical significance in the images of CanonÕ Rebel XT. CONCLUSIONS: The Hewlett PackardÕ Scan Jet 4C scanner with transparency reader and the SonyÕ DSC-W5 and CanonÕ Rebel XT/EOS cameras operating at 60 cm were shown appropriate for the digitization of cephalometric radiographs. In 25 cm, the digital cameras caused distortions in the image which altered the linear measurements with possibilities of jeopardizing the orthodontic diagnosis.


Assuntos
Cefalometria , Teste de Materiais , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia/métodos
8.
RGO (Porto Alegre) ; 58(2): 197-202, abr.-jun. 2010. tab, ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-874118

RESUMO

Objetivo: Verificar a prevalência de lesões compatíveis com odontoma em radiografias panorâmicas de pacientes atendidos na Clínica Radiológica do Centro de Pesquisas Odontológicas São Leopoldo Mandic, em Campinas (SP), entre 2003 e 2007. Métodos: Foi realizado um estudo radiográfico, retrospectivo, de 1 130 radiografias panorâmicas, sendo 1 077 convencionais e 53 digitais. Deste total, 580 eram de pacientes do gênero feminino e 550 do gênero masculino. Resultados: Em duas radiografias foram observadas imagens compatíveis com odontoma composto. Uma de paciente masculino, de 10 anos de idade, que apresentava o dente incisivo central superior direito não irrompido na maxila associado à imagem compatível com a lesão, e uma paciente feminino, de 16 anos, com canino inferior esquerdo não irrompido na mandíbula associado à imagem com dentículos. Conclusão: Os odontomas são tumores odontogênicos benignos, frequentemente, detectados em radiografias e cujas imagens, em decorrência das características patognomônicas, permitem o diagnóstico de odontoma composto.


Objective: The objective of this study was to verify the prevalence of lesions compatible with odontoma in the panoramic radiographs of patients seen at the Radiological Clinic of the São Leopold Mandic Research Center in Campinas, SP, Brazil, in the years 2003 to 2007. Methods: A retrospective radiographic study of 1130 panoramic radiographs was conducted where 1077 were conventional and 53 were digital. Of the total, 580 radiographs belonged to females and 550 to males. Results: The images of two radiographs were compatible with compound odontoma. One belonged to a 10-year-old boy who had an unerupted right maxillary central incisor associated with the image compatible with the lesion. The other belonged to a 16-year-old female patient who had an unerupted left mandibular canine associated with an image with denticles. Conclusion: Odontomas are benign odontogenic tumors frequently detected in radiographs and the images allow compound odontomas to be diagnosed because of their pathognomonic features.


Assuntos
Humanos , Masculino , Feminino , Odontoma/epidemiologia , Radiografia Panorâmica , Estudos Retrospectivos
9.
Ortho Sci., Orthod. sci. pract ; 3(10): 110-114, 2010. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-563024

RESUMO

As radiografias laterais cefalométricas têm relevante importância em Odontologia, sendo que existem no mercado diferentes equipamentos radiográficos que devem ser avaliados quanto à qualidade de imagem, a fim de promover uma análise cefalométrica de confiabilidade. No presente trabalho foi avaliado o grau de distorção em 16 radiografias cefalométricas, compararam-se as imagens obtidas de quatro crânios esqueletizados em quatro diferentes equipamentos radiográficos, analisando estatisticamente os resultados. Nos crânios foram fixados com cera utilidade 10 fios ortodônticos, com 1 mm de diâmetro, medindo 1 cm de comprimento, dispostos no sentido vertical e horizontal no rebordo alveolar superior e inferior do lado direito, e 3 esferas medindo 3 mm de diâmetro dispostas na maxila (lado direito) um pouco acima da linha de oclusão dos dentes. A análise comparativa dos resultados mostrou que as mensurações da magnificação variaram em média de 9,65 mm a 9,26 mm para os 10 fios ortodônticos, e em média de 3,60 mm a 3,12 mm para todas as medidas das 3 esferas, independente do lado de exposição ser o esquerdo ou direito. Verificamos que nenhum equipamento apresentou distorção de forma, e sim ampliação ou diminuição das estruturas medidas, e os equipamentos Gnatus e Rotograph foram os que mais ampliaram, provavelmente por apresentarem a maior distância objeto-filme...


The cephalometric lateral x-rays have excellent importance in Dentistry, being that radiographics equipment exists in the market different that must be evaluated how much to the quality of image, in order to promote a trustworthiness cephalometric analysis. In the present work the degree of distortion in 16 cephalometric x-rays was evaluated, had compared the gotten images of four dry skulls in four different radiographics equipment, analyzing statistical the results. In the skulls 10 orthodontic wires, with 1 mm of diameter, measuring 1 cm of length, made use in the vertical and horizontal direction in the upper/lower alveolar rim of the right side, and 3 spheres measuring 3 mm of diameter made use in the jaw had been fixed with wax utility (right side) a little above of the line of occlusion of teeth. The comparative analysis of the results showed that the measurements of the magnification had varied on average of 9,65 mm 9,26 mm for 10 orthodontic wires, and on average of 3,60 mm 3,12 mm for all the measures of the 3 spheres, independent of the exposition side to be the right or left. We verify that no equipment presented form distortion, and yes magnifying or reduction of the measured structures, and the equipment Gnatus and Rotograph had been the ones that they had more extended, probably for presenting the biggest distance object-film. The analysis descriptive statistics ANOVA and the tests post hoc of Bonferroni, Tamhane and Scheffé had shown as resulted, p = 0, for wires placed in the vertical line, where we can conclude that significant differences between the averages of the measures of the images of the four devices exist; for wires located in the horizontal line, as the value was of p = 0,9980...


Assuntos
Humanos , Equipamentos Odontológicos , Intensificação de Imagem Radiográfica
10.
RGO (Porto Alegre) ; 57(4): 385-388, out.-dez. 2009. ilus, graf, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-873856

RESUMO

Objetivo: Analisar as imagens radiográficas digitais usando os recursos disponíveis no Digora (Soredex, Helsinque, Finlândia), comparando com as imagens reais do sítio aberto cirurgicamente, variando ângulos das tomadas radiográficas, visando um resultado mais próximo do que seria o real. Métodos: Foram usadas para o exame clínico sondas milimetradas, com o auxílio de uma linha que une a junção amelocementária, medindo até o centro do defeito ósseo, entre dois dentes contíguos. O exame radiográfico foi padronizado para obter uma imagem digital com o maior detalhe e o mínimo de distorção, usando o suporte e posicionador do tipo Rinn e uma moldagem de resina das superfícies oclusais dos dentes a serem radiografados, para reproduzir as distâncias de 40cm foco/película, e o paralelismo objeto/filme, nas cinco incidências radiográficas utilizadas (0º, +10º, -10º, 10º à direita e 10º à esquerda). Resultados: Após o resultado estatístico descritivo, obtivemos o coeficiente de variação que se mostrou apenas regular, pois foi acima de 20%. Quanto ao tipo de tratamento da imagem, o DFW 2.5.1 mostrou a radiografia padrão, tendo resultados semelhantes ao exame clínico, a imagem radiográfica 3D, variações para menos e as imagens negativas para mais. Conclusão: A padronização usada na pesquisa para o exame radiográfico mostrou que sempre existe uma pequena ampliação da imagem em relação às medidas clínicas; que a mais confiável para a observação e medição das cristas ósseas interdentárias é a imagem padrão, seguida pela imagem 3D e finalmente a negativa, do sistema Digora de radiografia digital. A melhor incidência dos raios X, usando o posicionador tipo Rinn, é a de 0º, depois +10º, -10ºe 10º à direita; a incidência de 10º à esquerda é a que apresenta maior variação.


Objective: To analyze digital radiographic images using the resources available in the Digora digital radiograph system (Soredex, Helsinki, Finland), and comparing it with real images of the open surgical site, varying the angles of radiographs taken with the aim of obtaining a result closer to that which would be real. Methods: For the clinical exam, millimetric probes were used with the aid of a line that joins the amelocemental junction, measuring up to the center of the bone defect between two contiguous teeth. The radiographic exam was standardized to obtain a digital image with greater detail and the minimum of distortion, using a support and Rinn type positioner, and a resin model of the occlusal surfaces of the teeth to be radiographed, to reproduce the focus/film distances of 40cm, and object/film parallelism, in the five radiographic incidences used(0º, +10º, -10º, 10º to the right and 10º to the left). Results: After the descriptive statistical result the coefficient of variation was obtained, which was shown to be only regular, as it was over 20%. As regards the type of image treatment, DFW 2.5.a showed the standard radiograph to have similar results to those of the clinical exam, the 3D radiographic image had variations towards lower values and the negative images towards higher values. Conclusion: The standardization used in the research for radiographic exam showed that there is always a small enlargement of the image in relation to the clinical measurements; that the standard image was more reliable for the observation and measurement of interdental bone crests, followed by the 3D image and finally the negative image of the Digora digital radiographic system. The best incidence of X-rays, using the Rinn type positioner, is that of 0º, after this +10º, -10º and 10º to the right; the incidence of 10º to the left showed the greatest variation.


Assuntos
Humanos , Intensificação de Imagem Radiográfica/métodos , Perda do Osso Alveolar
11.
Rev. dent. press ortodon. ortopedi. facial ; 13(4): 86-91, jul.-ago. 2008. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-487768

RESUMO

OBJETIVO: diante da importância do sesamóide no emprego de métodos simplificados para a determinação da maturidade esquelética, julgamos necessário um estudo, em brasileiros adultos, para verificar a porcentagem de presença ou ausência deste ossículo. METODOLOGIA: a amostra constitui-se de 500 indivíduos brasileiros, com idade média de 22,5 (18-33) anos, de ambos os gêneros. A presença ou ausência do osso sesamóide foi verificada mediante a interpretação de radiografias periapicais, tomadas da articulação metacarpofalangena dos dois polegares de cada indivíduo da pesquisa. RESULTADOS E CONCLUSÃO: os resultados demonstraram que o osso sesamóide da articulação metacarpofalangeana esteve presente em todos os indivíduos (100 por cento) da amostra, concluindo, desta forma, que não houve agenesia deste osso nesta população avaliada.


AIM: the purpose of this study was to verify the percentage of agenesis of sesamoid bone in a Brazilian adult population. METHODS: the sample consisted of 329 females and 171 males, with mean age of 22.5 (range from 18 to 33 years). The presence or agenesis of sesamoid bone was evaluated through periapical radiographs taken from the metacarpophalangeal joint of the thumb (left and right) of each subject. RESULTS AND CONCLUSION: The results evidenced that the sesamoid bone was present in 100 percent of the sample, showing that was not found agenesis in these population.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Anodontia , Articulação Metacarpofalângica , Ossos Sesamoides/anormalidades , Determinação da Idade pelos Dentes , Distribuição por Etnia , Radiografia Dentária
12.
RGO (Porto Alegre) ; 56(1): 39-45, jan.-mar. 2008. tab
Artigo em Português | LILACS | ID: lil-482684

RESUMO

Objetivos: Determinar e analisar através de radiografias a incidência de anomalias dentais em pacientes portadores de fissura de lábio e/ou palato do Centro Pró-Sorriso da Universidade José do Rosário Vellano, Alfenas, Minas Gerais. Métodos: Radiografias periapicais e panorâmicas de 172 pacientes portadores de fissura de lábio e/ou palato, unilateral ou bilateral,completa e incompleta, na faixa etária de zero a 15 anos de idade, atendidos no Centro Pró-Sorriso, Universidade José do Rosário Vellano.Resultados: Noventa e oito (57,0%) apresentaram fissuras de lábio, alvéolo e palato; 32 (18,6%) apresentaram fissuras de lábio e alvéolo,28 (16,3%) fissuras de palato e 14 (8,1%) fissuras de lábio. O gênero masculino predominou em todos os tipos de fissuras, exceto nas fissuras de lábio do lado direito e de palato em que predominou o gênero feminino. Na relação entre etnia e o tipo de fissura não houve diferença significativa (X2= 4,28), sem considerar o lado de incidência. As maiores incidências de fissuras de lábio, alvéolo e palato, 47 (27,35%) foram do lado esquerdo, 31 (18,0%) bilaterais e 20 (11,6%) do lado direito. No grupo de fissuras de lábio e alvéolo 17 (9,9%) eram do lado esquerdo, 11 (6,4%) do lado direito e 4 (2,3%) bilateral. No grupo de fissuras de lábio 11 (6,4%) eram do lado esquerdo e 3 (1,7%) do lado direito. Conclusão: A incidência de fissuras de lábio, alvéolo e palato foram significativamente maior que a dos demais tipos de fissuras e o lado esquerdo prevaleceu sobre o lado direito e a modalidade bilateral. Foram encontradas 60,9% de agenesias dentais.


Objective: Analyze periapical and panoramic radiographs in order to define the incidence of dental agenesis in carriers of cleft lip and/or cleft palate among patients of UNIFENAS ?Centro Pró-Sorriso? (Pro-Smile Center) in Alfenas ? MG. Methods: Periapical and panoramic radiographs from recorders of 172 patients treated at Centro Pró-Sorriso (Center Pro-Smile) of UNIFENAS in Alfenas, Minas Gerais, for cleft lips and palates, unilateral or bilateral, complete or incomplete, in both genders, aged from 0 to 15 years. Results: From the total above mentioned 172 patients fulfilled the requirements, ninety eight (57.0%) presented cleft lips, alveoli andpalates. 32 (18.6%) presented cleft lip and alveolus cleft: 28 (16.3%) presented only cleft palate. 14 (8.1%) presented only cleft lip. Themasculine gender predominated in all types of cleft except for right lip and palate cleft, at which the feminine gender was preeminent. In the relation between ethnical characteristics and type of cleft, disregarding the side of incidence, no significant difference was noticed. The greatest incidence of cleft lip, alveolus (LAP) and palate occurred as follows: 47 (27.35%) on the left side; 31 (18.0%) were bilateral; 20 (11.6%) on the right side. In the group of lip and alveolus cleft, 17 (9.9%) were on the left side; 11 (6.4%) in the right side, and 4 (2.3%) were bilateral. In the group of lip cleft only, 11 (6.4%) were on the left side, and 3 (1.7%) in the right side. If the regions of incidence (right, left, bilateral) are considered, regardless of the type of cleft, the incidence on the left side was significantly greater than at right or the bilateral modality. No significant difference was noticed between the right side and the bilateral modality. Conclusion: he incidence of LAP cleft was significantly greater than that of the other types, and LA clefts were statistically more numerous than L cleft. With respect to LA clefts, the left side prevailed over the bilateral modality. 60.9% being of agenesis.


Assuntos
Humanos , Masculino , Feminino , Anodontia , Fenda Labial/complicações , Fissura Palatina/complicações , Radiografia Dentária , Radiografia Panorâmica , Fatores Sexuais
13.
J. Health Sci. Inst ; 24(3): 231-236, jul.-set. 2006. CD-ROM
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-873678

RESUMO

Este artigo apresenta revisão da literatura sobre o cisto retenção do seio maxilar descrevendo as características deste tipo de cisto mucoso. O fato de que outras lesões se pareçam com ele pode levar ao incorreto diagnóstico. O conhecimento da histologia e da fisiopatologia, bem como das características radiográficas são importantes para permitir que o diagnóstico precoce torne possível uma resolução favorável desta lesão


Assuntos
Cistos Maxilomandibulares , Diagnóstico Precoce , Seio Maxilar/lesões , Biópsia por Agulha , Cirurgia Bucal , Diagnóstico Bucal , Drenagem
14.
RGO (Porto Alegre) ; 54(2): 125-128, abr.-jun. 2006. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-457158

RESUMO

Este trabalho tem como objetivo analisar e comparar as imagens digitalizadas de forma indireta com as imagens apresentadas nas radiografias para verificar possíveis distorçães. Foram marcados pontos cefalométricos nas próprias radiografias e as distâncias entre os pontos medidas com dois tipos de paquímetro, um digital e outro analógico, sendo a média destas distâncias usada como parâmetro de referência para as medidas cefalométricas, mostrando as distorções que ocorrem em imagens digitalizadas indiretamente através de scanner. Utilizamos o software de cefalometria computadorizada, CEF X, para análise comparativa das imagens digitalizadas. O equipamento apresentou diferenças em relação aos paquímetros. Essas diferenças foram analisadas através de gráficos onde foi possível concluir a precisão do equipamento.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Intensificação de Imagem Radiográfica , Pesos e Medidas
15.
RGO (Porto Alegre) ; 54(2): 144-148, abr.-jun. 2006. ilus, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-457162

RESUMO

Este artigo tem como finalidade ajudar o cirurgião dentista a entender como é realizada a analise da estimativa de desenvolvimento ósseo através das vértebras da coluna cervical pelo método proposto por Hassel e Farman e realizar um comparativo entre o aumento de tamanho dos maxilares, o desenvolvimento ósseo e a idade cronológica. Através dos resultados obtidos conclui-se que a idade cronológica não é a mais apropriada para avaliar o desenvolvimento dos maxilares, o desenvolvimento ósseo mostrou um correlacionamento positivo com o crescimento dos maxilares.


Assuntos
Humanos , Masculino , Feminino , Desenvolvimento Ósseo , Desenvolvimento Maxilofacial , Intensificação de Imagem Radiográfica
16.
RPG rev. pos-grad ; 13(2): 175-180, abr.-jun. 2006. ilus, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-529357

RESUMO

O presente estudo verificou as condições de exposição e processamento radiográficos de filmes periapicais em 78 consultórios odontológicos no município de Balneário Camboriú, Santa Catarina, com o objetivo de analisar a qualidade da imagem radiográfica. Avaliaram-se 78 cirurgiões-dentistas, o correspondente a 86,7% dos profissionais do município. Para analisar a exposição radiográfica, foram verificados: o filme, a utilização de suportes porta-filme, os aparelhos de raios X e os resultados das radiografias obtidas. Para o processamento radiográfico, foram analisados: o tipo de câmara escura e o resultado das radiografias obtidas. Os resultados indicaram que 46% dos profissionais utilizavam filmes radiográficos periapicais de sensibilidade E; 57% não estavam fazendo uso dos suportes porta-filme; a maioria dos aparelhos encontrados foi da marca Dabi Atlante; 48% dos aparelhos verificados operavam com 70 kVp nominal; e 56% das radiografias apresentaram-se superexpostas, sendo que 35% estavam veladas. Somente 5% dos cirurgiões-dentistas utilizavam caixas portáteis de processamento opacas; 54% das radiografias estavam subprocessadas, sendo que 5% mostraram-se veladas. Esses dados permitiram concluir que a maioria dos profissionais avaliados estava realizando radiografias superexpostas e subprocessadas, além do mais, pequeno número dos cirurgiões-dentistas subexpõe o filme; quanto ao processamento, os resultados indicaram que os profissionais subprocessam as radiografias, na tentativa de adequá-las ao tempo de exposição excessivo para a obtenção da imagem radiográfica, sendo ainda responsáveis pela pequena quantidade de radiografias veladas, mesmo com a utilização de caixas portáteis de processamento inadequadas.


Assuntos
Controle de Qualidade , Exposição à Radiação , Radiografia Dentária , Consultórios Odontológicos , Proteção Pessoal/prevenção & controle , Proteção Radiológica , Filme para Raios X
17.
Rev. Fac. Odontol. Porto Alegre ; 47(1): 5-8, abr. 2006. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-457408

RESUMO

A qualidade da imagem radiográfica depende da correta indicação da técnica radiográfica, o tipo de filme utilizado, o tempo de exposição e o uso de soluções e locais de processamento adequados. O velamento radiográfico pode surgir em descuidos relacionados ao tempo de exposição, filmes deteriorados e através do processamento radiográfico. O objetivo do presente trabalho foi verificar as condições de exposição e processamento radiográficos quanto ao velamento. Os filmes foram expostos padronizadamente em um fantoma e, com a finalidade de avaliar o processamento radiográfico, foram processados nos consultórios odontológicos. Posteriormente, foram expostos filmes radiográficos usados, em rotina, pelos profissionais, em seus aparelhos de raios X com o tempo de exposição utilizado pelos mesmos. Após, estes filmes irradiados foram processados, padronizadamente, em uma processadora automática. Dessa maneira, pretendeu-se avaliar a exposição radiográfica. Após a obtenção das radiografias, foram feitas leituras das densidades ópticas (D.O.) na área de chumbo. Conclui-se que dos consultórios odontológicos avaliados, quase a metade das radiografias avaliadas apresentaram velamento quanto à exposição radiográfica e nenhuma apresentou velamento quanto ao processamento radiográfico.


Assuntos
Filme para Raios X/normas , Exposição à Radiação , Radiografia Dentária , Controle de Qualidade
18.
RGO (Porto Alegre) ; 53(4): 356-360, out.-dez. 2005. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-436254

RESUMO

O uso do scanner para a digitalização das imagens é consagrado, devido a sua fidelidade, porém, este método é lento e de alto custo. As máquinas fotográficas digitais passaram por um grande desenvolvimento tecnológico, o que pôde sugerir a sua utilização na captura de imagem para a cefalometria. Este estudo comparou dois métodos de captura indireta de imagem (scanner e máquina fotográfica digital), sendo que, as imagens do scanner foram consideradas como Grupo Controle. Foram utilizadas duas máquinas fotográficas digitais (Mavica FD-91 e DSC-707, ambas da Sony), cada uma com duas regulagens diferentes da lente: grande angular wide (W) e standart (S). Depois da captura das imagens, todas foram traçadas por um programa de cefalometria computadorizada (Radiocef 2000 - Brasil), e tiveram seus resultados comparados com o Grupo Controle. Após a análise estatística dos dados coletados, pode-se concluir que, a utilização da máquina fotográfica digital, substituindo o scanner, é perfeitamente possível, desde que se mantenha a regulagem da lente das máquinas fotográficas digitais no modo standart.


Assuntos
Humanos , Cefalometria/métodos , Processamento de Imagem Assistida por Computador/métodos , Radiografia Dentária Digital
19.
Rev. dent. press ortodon. ortopedi. facial ; 10(5): 130-136, set.-out. 2005. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-422897

RESUMO

A definição da posição do incisivo inferior oferece ao clínico dados para um correto planejamento e tratamento, assim como melhor estabilidade na pós-contenção. Observa-se, porém, que as análises cefalométricas mais utilizadas em Ortodontia para o diagnóstico geralmente são baseadas em indivíduos leucodermas, que diferem em características craniofaciais das outras raças. Desta forma, o presente trabalho teve como objetivo estudar o comportamento do incisivo inferior em relação às referências incisais preconizadas por Andrade (1-Jr), Interlandi (1-linhaI), Vigorito (1-linhaV) e Ricketts (1-linha AP) em jovens brasileiros melanodermas com oclusão normal, verificando também a ocorrência de dimorfismo sexual. Foram selecionadas 36 telerradiografias de cabeça tomadas em norma lateral de indivíduos brasileiros, melanodermas, na faixa etária de 10 a 14 anos, de ambos os gêneros, com oclusão clinicamente normal e que nunca se submeteram a tratamento ortodôntico, do Setor de Documentação Científica do Curso de Pós-Graduação em Ortodontia da FOP/UNICAMP, nas quais foram traçados os pontos, linhas e planos cefalométricos necessários para obtenção das referências incisais e medidas nas análises sugeridas pelos autores selecionados. Os valores médios obtidos para a posição do incisivo inferior diferiram entre si por duas análises estatísticas, havendo diferença significativa (p<0,05) entre os métodos estudados. Também não houve dimorfismo sexual. Concluiu-se que a posição dos incisivos inferiores em indivíduos jovens melanodermas brasileiros apresenta inclinação e vestibularização maior que a preconizada pelos autores consultados, e que a análise de referência incisal de Andrade (1-Jr) parece se comportar mais adequadamente para este grupo étnico.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Cefalometria , Etnicidade , Ortodontia
20.
RGO (Porto Alegre) ; 53(3): 217-219, jul.-set. 2005. ilus, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-427797

RESUMO

A qualidade da imagem radiográfica depende da correta indicação da técnica, o tipo de filme utilizado, o tempo de exposição e o uso de soluções e locais de processamento adequados. O objetivo do presente trabalho é verificar as condições do processamento radiográfico em consultórios odontológicos. Os filmes foram expostos padronizadamente em um fantoma e, com a finalidade de avaliar o processamento radiográfico, foram processados nos consultórios odontológicos. Após a obtenção das radiografias, foram feitas leituras das densidades ópticas (D.O.) na área de chumbo, alumínio e exposição direta. Concluiu-se que não houve velamento radiográfico e a maioria das radiografias estava sub-processada


Assuntos
Consultórios Odontológicos , Radiografia Dentária/normas , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...